Abstract
Abnormal phenomenon of output voltage is observed in a paralleled N+1 redundant DC-DC converter (DDC) system. The phenomenon is caused by a current sharing control under the condition of periodic load change, resulting in output-voltage increase. The mechanism of the phenomenon is analyzed with a circuit simulator and confirmed by experiment. A new type of current sharing circuit is proposed to solve the problem
Keywords
DC-DC power convertors; circuit simulation; electric current control; resonant power convertors; circuit simulator; current sharing circuit; current sharing control; output-voltage; parallel-redundant DC-DC converter system; periodic load change; Analytical models; Circuit analysis; Circuit simulation; Control systems; DC-DC power converters; Impedance; Mission critical systems; Power supplies; Power system reliability; Voltage control;