DocumentCode
2039329
Title
Digital simulation of electromagnetic flowmeter for insulating liquids
Author
Liang, B.
Author_Institution
Manchester Metropolitan Univ., UK
fYear
2002
fDate
2002
Firstpage
309
Lastpage
311
Abstract
This paper presents a digital simulation for a electromagnetic flowmeter which could be used for conducting, low conducting and non-conducting liquids. The digital simulated results show that the low level flow signal could be recovered in the high level background noise associated with the low. or non-conducting liquids if a dual frequency driving and the appropriate digital bandpass filters and phase sensitive detectors are used.
Keywords
band-pass filters; dielectric liquids; digital filters; digital simulation; electromagnetic devices; flowmeters; signal processing; conducting liquids; digital bandpass filters; digital simulation; dual frequency driving; electromagnetic flowmeter; high level background noise; insulating liquids; low conducting liquids; low level flow signal; nonconducting liquids; phase sensitive detectors; Dielectric liquids; Digital simulation; Electromagnetic measurements; Fluid flow measurement; Frequency; Insulation; Magnetic flux; Magnetic separation; Phase detection; Signal processing;
fLanguage
English
Publisher
ieee
Conference_Titel
Dielectric Liquids, 2002. ICDL 2002. Proceedings of 2002 IEEE 14th International Conference on
Print_ISBN
0-7803-7350-2
Type
conf
DOI
10.1109/ICDL.2002.1022756
Filename
1022756