DocumentCode
2040577
Title
How serious is the issue of backside Cu contamination in CMOS integrated circuits?
Author
Prasad, Krishnamachar
Author_Institution
Sch. of Electr. & Electron. Eng., Nanyang Technol. Univ., Singapore
fYear
2000
fDate
2000
Firstpage
25
Lastpage
28
Abstract
Experimental results are presented on the effects of intentional copper contamination on the performance of NMOS and PMOS devices in CMOS integrated circuits (ICs). Intentional copper contamination was introduced from the wafer backside using either PVD copper, or CuSO4 electroplating solution or copper ion implantation. High temperature annealing was carried out to drive-in the copper species. Regardless of the method of intentional copper contamination, there was little or no change in the electrical parameters of both NMOS and PMOS devices. Secondary Ion Mass Spectroscopy (SIMS) analysis showed that very little copper diffused into silicon, leading to no device degradation.
Keywords
CMOS integrated circuits; annealing; copper; diffusion; integrated circuit metallisation; secondary ion mass spectra; surface contamination; CMOS integrated circuit; Cu; Cu metallization; CuSO4 electroplating solution; NMOS device; PMOS device; PVD copper; SIMS analysis; backside Cu contamination; copper diffusion; copper ion implantation; device degradation; electrical parameters; high temperature annealing; Annealing; Atherosclerosis; CMOS integrated circuits; Contamination; Copper; Ion implantation; MOS devices; Mass spectroscopy; Silicon; Temperature;
fLanguage
English
Publisher
ieee
Conference_Titel
Optoelectronic and Microelectronic Materials and Devices, 2000. COMMAD 2000. Proceedings Conference on
Print_ISBN
0-7803-6698-0
Type
conf
DOI
10.1109/COMMAD.2000.1022884
Filename
1022884
Link To Document