• DocumentCode
    2040577
  • Title

    How serious is the issue of backside Cu contamination in CMOS integrated circuits?

  • Author

    Prasad, Krishnamachar

  • Author_Institution
    Sch. of Electr. & Electron. Eng., Nanyang Technol. Univ., Singapore
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    25
  • Lastpage
    28
  • Abstract
    Experimental results are presented on the effects of intentional copper contamination on the performance of NMOS and PMOS devices in CMOS integrated circuits (ICs). Intentional copper contamination was introduced from the wafer backside using either PVD copper, or CuSO4 electroplating solution or copper ion implantation. High temperature annealing was carried out to drive-in the copper species. Regardless of the method of intentional copper contamination, there was little or no change in the electrical parameters of both NMOS and PMOS devices. Secondary Ion Mass Spectroscopy (SIMS) analysis showed that very little copper diffused into silicon, leading to no device degradation.
  • Keywords
    CMOS integrated circuits; annealing; copper; diffusion; integrated circuit metallisation; secondary ion mass spectra; surface contamination; CMOS integrated circuit; Cu; Cu metallization; CuSO4 electroplating solution; NMOS device; PMOS device; PVD copper; SIMS analysis; backside Cu contamination; copper diffusion; copper ion implantation; device degradation; electrical parameters; high temperature annealing; Annealing; Atherosclerosis; CMOS integrated circuits; Contamination; Copper; Ion implantation; MOS devices; Mass spectroscopy; Silicon; Temperature;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Optoelectronic and Microelectronic Materials and Devices, 2000. COMMAD 2000. Proceedings Conference on
  • Print_ISBN
    0-7803-6698-0
  • Type

    conf

  • DOI
    10.1109/COMMAD.2000.1022884
  • Filename
    1022884