Title :
Analysis of inclusions at materials by metrotomography
Author :
Glittova, Darina ; Toth, Teodor ; Zivcak, Jozef
Author_Institution :
Dept. of Biomed. Eng. & Meas., Tech. Univ. of Kosice, Kosice, Slovakia
Abstract :
The aim of this work is to analyze inclusions of samples from selected materials using metrotomography. The main part of the problem was correct methodology of software processing of the measured data acquired by computed tomography equipment Carl Zeiss METROTOM1500. For various settings of the input parameters was investigated expected output data to a known set of defects. Comparison of the effects of setting on results of the assessment should help in setting parameters for evaluation of defects in industrial applications.
Keywords :
computerised tomography; inclusions; materials science computing; materials testing; Carl Zeiss METROTOM1500; computed tomography equipment; defect evaluation; inclusion analysis; industrial applications; metrotomography; software processing; Algorithm design and analysis; Biomedical measurement; Computed tomography; Materials; Noise reduction; Probability; Software;
Conference_Titel :
Applied Machine Intelligence and Informatics (SAMI), 2015 IEEE 13th International Symposium on
Conference_Location :
Herl´any
DOI :
10.1109/SAMI.2015.7061847