DocumentCode
2045624
Title
Continuous Noninvasive Blood Pressure Measurement by Near Infra Red CCD Camera and Pulse Transmit Time Systems
Author
Zurek, Petr ; Krejcar, Ondrej ; Penhaker, Marek ; Cerny, Martin ; Frischer, Robert
Author_Institution
Dept. of Meas. & Control, VSB Tech. Univ. of Ostrava, Ostrava, Czech Republic
Volume
2
fYear
2010
fDate
19-21 March 2010
Firstpage
449
Lastpage
453
Abstract
The need of continuous blood pressure measurement is usable in wide spectrum of applications from physicians practice to home care applications. Many types of blood pressure measurement devices can be bought in electronics shops. All such devices are contact measurement devices which need to be in contact of human body (hand or foot mainly). Secondary they allow only one measurement per several minutes interval (typically ones in 10 minutes). Our goal is to develop a small device for noninvasive continuous measurement of blood pressure. This device must be a small battery powered embedded system which measure a blood pressure during a long time period and send this information remotely to operator´s stations. We would like to try two systems of blood pressure monitoring. The first one is system with NIR CCD camera (Near Infra Red), which measure the wide changes of the blood vessels and the second one is system, which measure the pulse transmit time (PTT). At the end we can compare the systems and get information, which system will be a right way to obtain exact continuous blood pressure information.
Keywords
blood pressure measurement; blood vessels; cameras; patient monitoring; blood pressure monitoring; blood vessels; contact measurement devices; continuous noninvasive blood pressure measurement; exact continuous blood pressure information; foot; hand; human body; near infra red CCD camera; noninvasive continuous measurement; operator stations; pulse transmit time; pulse transmit time systems; small battery powered embedded system; Battery charge measurement; Biomedical monitoring; Blood pressure; Charge coupled devices; Charge-coupled image sensors; Foot; Humans; Pressure measurement; Pulse measurements; Time measurement; Analyzer; Blood; Mobile Device; NIR CC; PTT; Pressure;
fLanguage
English
Publisher
ieee
Conference_Titel
Computer Engineering and Applications (ICCEA), 2010 Second International Conference on
Conference_Location
Bali Island
Print_ISBN
978-1-4244-6079-3
Electronic_ISBN
978-1-4244-6080-9
Type
conf
DOI
10.1109/ICCEA.2010.236