  • Abstract
    This paper reports an optimisation algorithm based upon the simulated annealing technique for a hybrid energy system. The hybrid energy system is an integrated diesel-generator/battery-inverter system developed for remote communities where the supply of the main electrical power is unavailable. The developed algorithm provides optimal generator setting and battery charge/discharge schedules for a given daily load cycle. It has been applied to a test example and the simulation results are presented.<>
  • Keywords
    battery chargers; battery storage plants; diesel-electric generators; invertors; power convertors; simulated annealing; battery charge/discharge schedules; daily load cycle; diesel generator/battery-inverter power system; generator setting; hybrid energy system; optimisation algorithm; remote communities; simulated annealing; Australia; Batteries; Control systems; Costs; Power generation; Power grids; Power supplies; Pulse width modulation inverters; Scheduling algorithm; Simulated annealing;