Title :
Effect of integrated mast on power quality of naval vessel in island configuration
Author :
Bijman, Rob ; Timens, R.B. ; Leferink, Frank
Author_Institution :
Thales Nederland B.V., Hengelo, Netherlands
Abstract :
Analysis and measurements have been performed to justify the use of Commercial Off The Shelf products in combination with the power network of a naval vessel. It was concluded that the onboard supply is well controlled and suitable for such applications, except for harmonic distortion, which exceeds the limits in civil and military standards. Measurements were first performed without the integrated mast on the vessel. The integrated mast contains a variety of antennas and control cabinets, which could have an additional effect on the power quality of the island network configuration present inside the vessel. During a second measurement series, power quality measurements with respect to civil and military standards have been performed in order to verify the effect of the integrated mast. It was shown that the naval power network of the vessel including integrated mast, which is normally designed and tested against military standards only, also meets civil standards suitable for the placement of COTS equipment.
Keywords :
harmonic distortion; marine power systems; power supply quality; power system harmonics; power system measurement; civil standards; harmonic distortion; integrated mast; island network configuration; military standards; naval power network; naval vessel; onboard supply; power quality measurements; Distortion measurement; Electromagnetic compatibility; Harmonic analysis; Harmonic distortion; Power harmonic filters; Power quality; Standards;
Conference_Titel :
Electromagnetic Compatibility (EMC EUROPE), 2013 International Symposium on
Conference_Location :
Brugge