Title :
DC pollution of AC mains due to modern compact fluorescent light lamps and LED lamps
Author :
Keyer, Cees ; Timens, Roelof ; Buesink, Frits ; Leferink, Frank
Author_Institution :
Univ. of Twente, Enschede, Netherlands
Abstract :
Modern so-called energy efficient equipment often draw current only during a very short period of the period of a power supply mains. This is causing unwanted non-sinusoidal and harmonic currents. In some cases even a single diode is used for rectification causing direct current (DC) in the mains supply. To reduce dissipation the semiconductor components switch very fast, which is causing interference, especially in medium- and high-frequency communication systems. The pollution in the mains supply due to energy efficient LED and compact florescent lamps is shown and discussed.
Keywords :
LED lamps; fluorescent lamps; rectification; ac mains; compact florescent lamps; dc pollution; energy efficient LED lamps; energy efficient equipment; harmonic currents; high-frequency communication systems; interference; modern compact fluorescent light lamps; nonsinusoidal currents; rectification; semiconductor components; Current measurement; Electromagnetic compatibility; Energy efficiency; Europe; Harmonic analysis; LED lamps; Switches; DC current in grid; LED lamps; energy efficient lighting; grid pollution;
Conference_Titel :
Electromagnetic Compatibility (EMC EUROPE), 2013 International Symposium on
Conference_Location :
Brugge