• DocumentCode
    2050079
  • Title

    Comparison of finite integration technique (FIT) and transmission line matrix (TLM) for numerical dosimetry in HF/VHF band

  • Author

    Laisne, Alexandre ; Drouet, Julien

  • Author_Institution
    DGA Tech. Aeronautiques, Balma, France
  • fYear
    2013
  • fDate
    2-6 Sept. 2013
  • Firstpage
    659
  • Lastpage
    664
  • Abstract
    This paper presents a synthesis of results obtained by DGA TA regarding numerical dosimetry in HF / VHF band. The variations of the basic restrictions with model (Hugo, Ella and Duke), voxel resolution, meshsize, and contacts are considered. A particular focus is brought on the influence of the numerical method, through a comparison of FIT and TLM. Results show that the TLM method is particularly well suited for numerical dosimetry with highly heterogeneous structures.
  • Keywords
    dosimetry; transmission line matrix methods; FIT; HF/VHF band; TLM; finite integration technique; numerical dosimetry; transmission line matrix; voxel resolution; Computational modeling; Current density; Electromagnetic compatibility; Europe; Numerical models; Time-domain analysis; Time-varying systems; FIT and TLM Methods; ITIS base; Numerical dosimetry;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility (EMC EUROPE), 2013 International Symposium on
  • Conference_Location
    Brugge
  • ISSN
    2325-0356
  • Type

    conf

  • Filename
    6653384