Harmonic measurement and modeling for mass implementation of nonlinear appliances
Author :
Koch, A.S. ; Myrzik, J.M.A. ; Wiesner, T. ; Jendernalik, L.
fYear :
2012
fDate :
22-26 July 2012
Firstpage :
1
Lastpage :
6
Abstract :
In order to analyze the effects of a widespread use of nonlinear appliances harmonic measurements are done on specific examples like compact fluorescent lamps (CFL) and photovoltaic (PV) inverters. The results of the investigation determine requirements on nonlinear models, which are necessary to consider the impact of mass implementation. Particularly, the voltage and operating point dependency of the harmonic currents are taken into account. Furthermore, this paper provides an overview of existing nonlinear models and emphasizes their advantages and disadvantages. Thereby, the main focus is on models, which uses a measurement based approach.
Keywords :
domestic appliances; electric current measurement; fluorescent lamps; invertors; mass measurement; CFL; PV inverter; compact fluorescent lamp; harmonic current dependency; harmonic measurement; harmonic modeling; mass implementation; nonlinear appliance; photovoltaic inverter; Current measurement; Distortion measurement; Harmonic analysis; Harmonic distortion; Inverters; Power system harmonics; Voltage measurement; Harmonic measurements; nonlinear models;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power and Energy Society General Meeting, 2012 IEEE
Conference_Location :
San Diego, CA
ISSN :
1944-9925
Print_ISBN :
978-1-4673-2727-5
Electronic_ISBN :
1944-9925
Type :
conf
DOI :
10.1109/PESGM.2012.6345068
Filename :
6345068
Link To Document :
بازگشت