• DocumentCode
    2053187
  • Title

    MR imaging with 3D fast spin echo using projection reconstruction: technique description and applications

  • Author

    Alexander, A.L. ; Roberts, J. ; Kholmovski, E. ; Parker, D.L.

  • Author_Institution
    Med. Imaging Res. Lab., Utah Univ., Salt Lake City, UT, USA
  • Volume
    2
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    1087
  • Abstract
    Conventional Fourier transform MR imaging techniques are highly sensitive to motion artifacts, particularly for applications such as imaging the neck (breathing, swallowing, cardiovascular pulsatility), the abdomen and diffusion-weighted imaging. In this study, the authors describe a novel 3D imaging technique which combines a 3D fast spin echo with a projection reconstruction acquisition. Projection reconstruction techniques demonstrate less objectionable motion artifacts compared with conventional Fourier transform MRI techniques. In this implementation, the FSE readout gradients are modified to collect projection data in the x-y plane. The projection angle is fixed and the slice-encoding gradient in z is modulated during the echo train. The projection angle is incremented for each new echo train series. Since the acquisition is 3D, it will have improved signal-to-noise over comparable 2D acquisitions. The primary disadvantage to the technique is the increased blurring in the slice-encode direction that results from the T2-weighting of the slice-encoded echoes. The technique was demonstrated on both a phantom and the neck of a human volunteer. The acquisition technique may be useful for the applications of high-resolution carotid black-blood imaging as well as diffusion-weighted imaging of the human brain
  • Keywords
    biomedical MRI; blood; brain; image coding; image reconstruction; medical image processing; 3D fast spin echo using projection reconstruction; abdomen; acquisition technique; breathing; cardiovascular pulsatility; conventional Fourier transform MRI techniques; diffusion-weighted imaging; high-resolution carotid black-blood imaging; human brain; human volunteer; magnetic resonance imaging; medical diagnostic imaging; motion artifacts; neck; projection reconstruction acquisition; slice-encoding gradient; swallowing; x-y plane; Biomedical imaging; Fourier transforms; High-resolution imaging; Humans; Image reconstruction; Imaging phantoms; Magnetic resonance imaging; Neck; Radiology; Slabs;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium, 1999. Conference Record. 1999 IEEE
  • Conference_Location
    Seattle, WA
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-5696-9
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1999.845849
  • Filename
    845849