DocumentCode
2053370
Title
Separation of overlapping activity in first and second somatosensory evoked fields with 3-D MEG measurement
Author
Kim, B.S. ; Kobayashi, K. ; Uchikawa, Y.
Author_Institution
Toho Denki Univ., Saitama, Japan
fYear
2003
fDate
March 30 2003-April 3 2003
Abstract
In this article, we conclude that singular value decomposition (SVD) analysis, having different frequency ranges, is useful for separating the secondary somatosensory activity from the primary somatosensory activity overlapping in time. We carried out 3D MEG measurement of somatosensory evoked field (SEF) with the electric stimulus to the right thumb.
Keywords
magnetoencephalography; singular value decomposition; somatosensory phenomena; 3D MEG measurement; electric stimulus; overlapping activity; primary somatosensory activity; secondary somatosensory activity; singular value decomposition analysis; somatosensory evoked field; Delay; Erbium; Frequency; Physics;
fLanguage
English
Publisher
ieee
Conference_Titel
Magnetics Conference, 2003. INTERMAG 2003. IEEE International
Conference_Location
Boston, MA, USA
Print_ISBN
0-7803-7647-1
Type
conf
DOI
10.1109/INTMAG.2003.1230745
Filename
1230745
Link To Document