DocumentCode
2057226
Title
Study on the wave form of leakage current on the 20 kV post-pin ceramic insulators under various conditions
Author
Suwarno
Author_Institution
Dept. of Electr. Eng., Inst. Teknologi Bandung, Indonesia
fYear
2001
fDate
2001
Firstpage
387
Lastpage
390
Abstract
This paper reports the results of investigation on the wave forms of leakage current (LC) on the 20 kV-post-pin ceramics insulators under various conditions. The measurement was conducted by utilizing a computer-based measurement system. analysis of LC harmonics was done by applying fast Fourier transform (FFT). Total harmonic distortion (THD) was used to quantify the harmonics content of the LC. The results show that the magnitude as well as the wave form and THD of the LC were significantly correlated with the condition of the insulator surfaces
Keywords
ceramic insulators; electric current measurement; fast Fourier transforms; harmonic analysis; harmonic distortion; insulator testing; leakage currents; 20 kV; THD; ceramic insulators; computerbased measurement system; fast Fourier transform; insulator surfaces; leakage current harmonics analysis; leakage current waveforms; post-pin ceramics insulators; surface condition; total harmonic distortion; Ceramics; Dielectrics and electrical insulation; Distortion measurement; Harmonic analysis; Humidity; Leakage current; Pollution measurement; Surface contamination; Total harmonic distortion; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulating Materials, 2001. (ISEIM 2001). Proceedings of 2001 International Symposium on
Conference_Location
Himeji
Print_ISBN
4-88686-053-2
Type
conf
DOI
10.1109/ISEIM.2001.973682
Filename
973682
Link To Document