    Concentrated Wound Permanent Magnet Machines with Different Rotor Designs

  • Author

    Salminen, P. ; Pyrhönen, J. ; Jussila, H. ; Niemelä, M.

  • Author_Institution
    Lappeenranta University of Technology, Department of Electrical Engineering, P.O. Box 20 FIN-53851 Lappeenranta, Finland. E-mail: Pia.Salminen@lut.fi
  • fYear
    2007
  • fDate
    12-14 April 2007
  • Firstpage
    514
  • Lastpage
    517
  • Abstract
    Concentrated wound permanent magnet machines are designed with two different rotor constructions: either surface-mounted magnets or embedded magnets are sssused in the rotor. Five different types of concentrated wound PM motors with both rotor types are studied. The motors under investigation are 12-slot-8-pole, 12-slot-10-pole, 24-slot-22-pole, 24-slot-20-pole, and 36-slot-30-pole ones. It is in the authors´ interest to find out which of the concentrated wound PM motors would be the best choice for a certain application. The studied motors are designed for a low-speed application with about 45 kW output power. Both analytic and finite element computations are made. Machine characteristics are studied under rated load and the maximum torques of the motors are estimated.
  • Keywords
    Coils; Copper; Costs; Iron; Machine windings; Permanent magnet machines; Permanent magnet motors; Rotors; Torque; Wounds;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Engineering, Energy and Electrical Drives, 2007. POWERENG 2007. International Conference on
  • Conference_Location
    Setubal, Portugal
  • Print_ISBN
    978-1-4244-0895-5
  • Electronic_ISBN
    978-1-4244-0895-5
  • Type

    conf

  • DOI
    10.1109/POWERENG.2007.4380168
  • Filename
    4380168