• DocumentCode
    2057756
  • Title

    Water tree retardant characteristics of silane crosslinked polyethylene

  • Author

    Thanh, Vu Hai ; Hozumi, Naohiro ; Nagao, Masayuki ; Goto, Toshihiro ; Kato, Yoshio

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Toyohashi Univ. of Technol., Japan
  • fYear
    2001
  • fDate
    2001
  • Firstpage
    467
  • Lastpage
    470
  • Abstract
    Water tree retardant characteristics of silane crosslinked polyethylene (PE) was investigated by measuring dc leakage currents, observing tree shapes and analyzing aging time dependence of tree number and tree length distribution. It seems to be more difficult for water trees to develop in silane crosslinked PE. Here, it is considered that pendent silane plays role of water tree retardant. The condensed silanol groups among PE molecules might act as obstruction to water tree initiation and growth
  • Keywords
    XLPE insulation; ageing; leakage currents; trees (electrical); DC leakage current; aging; silane crosslinked polyethylene; water tree retardant characteristics; Aging; Cable insulation; Chemicals; Electrodes; Polyethylene; Polymers; Retardants; Testing; Trees - insulation; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulating Materials, 2001. (ISEIM 2001). Proceedings of 2001 International Symposium on
  • Conference_Location
    Himeji
  • Print_ISBN
    4-88686-053-2
  • Type

    conf

  • DOI
    10.1109/ISEIM.2001.973704
  • Filename
    973704