DocumentCode
2061144
Title
Selection Methodology of A/D Converters for a Wide Dynamic Range Data Acquisition System
Author
Chatt, B.
Author_Institution
Africa PetroTel Inc., Piano
fYear
2007
fDate
20-22 April 2007
Firstpage
441
Lastpage
444
Abstract
With the extensive use of digital measurement devices for measuring several power system parameters by a common data acquisition system, the need for a wide dynamic range data acquisition system has become critical. The design of such data acquisition system should be done carefully so that small neutral current, normal load current, and high level of fault current can be measured without compromising the accuracy. This paper discusses a methodology by which a proper data acquisition system can be designed with wide dynamic range.
Keywords
data acquisition; power convertors; power system measurement; A/D converters selection methodology; digital measurement devices; fault current; neutral current; normal load current; power system parameters; wide dynamic range data acquisition system; Attenuation measurement; Costs; Current measurement; Current transformers; Data acquisition; Delta-sigma modulation; Dynamic range; Fault currents; Monitoring; Power measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Region 5 Technical Conference, 2007 IEEE
Conference_Location
Fayetteville, AR
Print_ISBN
978-1-4244-1280-8
Electronic_ISBN
978-1-4244-1280-8
Type
conf
DOI
10.1109/TPSD.2007.4380404
Filename
4380404
Link To Document