DocumentCode :
2061192
Title :
The infrared thermal converter as a highly precise transfer standard
Author :
Castelli, Franco
Author_Institution :
Dipartimento di Elettrotecnica, Politecnico di Milano, Italy
Volume :
1
fYear :
1996
fDate :
1996
Firstpage :
206
Abstract :
The new thermal converter developed has the following AC-DC transfer errors: lower than 2.5·10-4 ppm (1 σ) at frequencies from DC to 75 kHz; equal to: 10-3 ppm 100 kHz and to 0.01 ppm at 125 kHz. The design is based on an infrared thermal sensor irradiated by a “flat strap sandwich heater resistor” (FSSHR). The high accuracy results qualify the converter as a possible AC-DC reference transfer standard
Keywords :
calibration; current comparators; electric current measurement; infrared detectors; measurement standards; temperature sensors; voltage measurement; 100 kHz; 125 kHz; AC-DC transfer errors; calibration; current comparator; flat strap sandwich heater resistor; highly precise transfer standard; infrared thermal converter; infrared thermal sensor; reference transfer standard; shunt; thermal loss; Analog-digital conversion; Frequency conversion; Infrared heating; Infrared sensors; Measurement standards; Resistors; Tellurium; Testing; Thermal resistance; Thermal sensors;
fLanguage :
English
Publisher :
ieee