• DocumentCode
    2065333
  • Title

    Space Qualification of the Radioastron 22 GHz Receiver

  • Author

    Piironen, P. ; Mallat, J. ; Rasanen, A. ; Siivola, E. ; Takala, J. ; Jukkala, P. ; Sailamäki, P. ; Somerma, H. ; Ylinen, J.

  • Author_Institution
    Helsinki University of Technology, Radio Laboratory, Otakaari 5 A, SF-02150 Espoo, Finland
  • Volume
    1
  • fYear
    1992
  • fDate
    5-9 Sept. 1992
  • Firstpage
    305
  • Lastpage
    310
  • Abstract
    The Radioastron space VLBI satellite, expected to be launched in 1995, will have on board four sensitive two-channel radiometers. Finland is responsible for the 22 GHz receiver. The most important properties of the receiver are sensitivity, phase stability and gain stability. To reach maximum sensitivity, a modern space qualified low noise HEMT amplifier has been designed. The measured receiver noise temperature is 140 K. For maximum phase and amplitude stabilities, temperature stabilisation and a high Q dielectric resonator oscillator design have been utilized. The measured phase stability is better than 3 o/h. The main aspects of the space qualification tests and the reliability analysis are described.
  • Keywords
    Dielectric measurements; HEMTs; Low-noise amplifiers; Phase measurement; Qualifications; Radiometers; Satellite broadcasting; Stability; Temperature measurement; Temperature sensors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Conference, 1992. 22nd European
  • Conference_Location
    Helsinki, Finland
  • Type

    conf

  • DOI
    10.1109/EUMA.1992.335685
  • Filename
    4135468