Abstract :
In This work the estimation of the usefulness of the Weston cells as the electrical voltage reference group measure standard in the hierarchical arrangement verification system are given. All Weston cells for which the measurements results are described in the paper were calibrated at Bureau International Des Poids et measures (BIPM) and the calibration results are taken into account for the analysis. The purpose of the analysis had been the answer to the question whether the Weston cells can be used in the hierarchical arrangement verification system as the voltage reference group measure standards.
Keywords :
calibration; measurement standards; measurement uncertainty; voltage measurement; Bureau International des Poids et Measures; Weston cells estimation; calibration; electrical voltage reference group measure standards; hierarchical arrangement verification system; measurement uncertainty; metrological characteristics; Calibration; Central office; Electric variables measurement; Linear regression; Measurement standards; Metrology; Noise measurement; Numerical analysis; Voltage measurement; White noise;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Modern Problems of Radio Engineering, Telecommunications and Computer Science, 2004. Proceedings of the International Conference
Conference_Location :
Lviv-Slavsko, Ukraine
Print_ISBN :
966-553-380-0
Type :
conf
Filename :
1365942
Link To Document :
بازگشت