DocumentCode
2069573
Title
The detection of interturn short circuits in the stator windings of operating motors
Author
Joksimovic, Gojko ; Penman, Jim
Author_Institution
Dept. of Eng., Aberdeen Univ., UK
Volume
4
fYear
1998
fDate
31 Aug-4 Sep 1998
Firstpage
1974
Abstract
The detection of shorted turns in a stator winding is possible in a variety of ways. The analysis of the motor current to perform this function is particularly attractive however, since current sensors are usually installed together with the motor for control and protection purposes. A winding function based method for modelling polyphase cage induction motors with this type of asymmetry is developed, and it is shown that the stator winding itself can be used as a sensor for detection of this type of fault. An experimental setup comprising a 3 kW delta connected motor loaded by a generator was used to validate this approach. The experimental results obtained clearly validated the theory
Keywords
fault location; short-circuit currents; squirrel cage motors; stators; 3 kW; current sensors; delta connected motor; generator load; interturn short circuits detection; motor current analysis; operating motors; polyphase cage induction motors; stator winding; stator windings; winding function based method; Bars; Circuits; Equations; Induction motors; Insulation; Machine windings; Protection; Rotors; Stator windings; Torque;
fLanguage
English
Publisher
ieee
Conference_Titel
Industrial Electronics Society, 1998. IECON '98. Proceedings of the 24th Annual Conference of the IEEE
Conference_Location
Aachen
Print_ISBN
0-7803-4503-7
Type
conf
DOI
10.1109/IECON.1998.724020
Filename
724020
Link To Document