  • Abstract
    This paper presents an approach to determine the main parameters used in a double-pulse excitation applied to a piezoceramic ultrasonic transducer to produce a short received signal. A computer simulation is also presented to illustrate the excellent results obtained even when the transducer is not well matched to the backing material nor to the transmission medium. The double-pulse excitation is much easier to generate than the complex excitation waveforms used in the literature for shortening the acoustic pulse. Hence, the electronic circuitry involved is simplified
  • Keywords
    SPICE; acoustic signal processing; acoustic transducers; digital simulation; optimisation; piezoceramics; piezoelectric transducers; simulation; ultrasonic transducers; acoustic pulse; backing material; complex excitation waveforms; computer simulation; double-pulse excitation; frequency response; optimisation; piezoceramic ultrasonic transducer; short pulse generation; short received signal; Acoustic emission; Acoustic pulses; Acoustic transducers; Biomedical transducers; Circuits; Frequency domain analysis; Piezoelectric materials; Piezoelectric transducers; Pulse generation; Ultrasonic transducers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference, 1996. IMTC-96. Conference Proceedings. Quality Measurements: The Indispensable Bridge between Theory and Reality., IEEE
  • Conference_Location
    Brussels
  • Print_ISBN
    0-7803-3312-8
  • Type

    conf

  • DOI
    10.1109/IMTC.1996.507413
  • Filename
    507413