  • Abstract
    A novel measurement method has been developed to characterize the common-mode (CM) and differential-mode (DM) impedances of power line EMI chokes under realistic loading conditions. With a proper pre-measurement calibration process, all parasitic effects in the measurement setup can be eliminated. The measurement allows designer to assess the EMI suppression performance of these chokes with reasonable accuracy under various loading conditions. With the measurement results, a proper choke with optimum EMI suppression performance could be selected for a specific loading condition.
  • Keywords
    electric impedance measurement; electromagnetic interference; inductors; interference suppression; power filters; EMI chokes; EMI suppression; common-mode impedances; differential-mode impedances; power line; premeasurement calibration process; realistic loading conditions; Coupling circuits; Current measurement; Delta modulation; Electromagnetic interference; Impedance measurement; Inductors; Magnetic separation; Power measurement; Probes; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility and 19th International Zurich Symposium on Electromagnetic Compatibility, 2008. APEMC 2008. Asia-Pacific Symposium on
  • Conference_Location
    Singapore
  • Print_ISBN
    978-981-08-0629-3
  • Electronic_ISBN
    978-981-08-0629-3
  • Type

    conf

  • DOI
    10.1109/APEMC.2008.4559980
  • Filename
    4559980