• DocumentCode
    2075944
  • Title

    Characteristics and electric contact behavior of tarnished film covered on silver plated surface formed by indoor air exposure

  • Author

    Zhang, J.G. ; Lin, X.Y. ; Sugimura, K.

  • Author_Institution
    Res. Lab. of Electr. Contacts, Beijing Univ. of Posts & Telecommun., China
  • fYear
    1996
  • fDate
    16-20 Sept. 1996
  • Firstpage
    429
  • Lastpage
    437
  • Abstract
    Previous experimental results showed that seriously contaminated films were found on silver contact surfaces which caused electric contact failure. To investigate the tarnished film formed by natural air exposure, silver plated coupons were exposed indoors for 18 months. Tarnished ring patterns with various sizes were observed. The thickness of the film on ring area was as high as 1500 A and a polarity effect was also found. The composition mainly seems to be copper sulfide. The contact resistance on outside ring areas appeared lower than that on the ring areas but they were still beyond the normal value. The inside ring areas looked to be least corroded. Sliding contact behavior showed high resistance and only part of the film was peeled away. The existence of copper on the surface is believed to result from the corroded copper products which have crept through the tiny holes and micro-cracks in the silver plating and nickel underplates. A circular ring stain pattern was formed probably due to water droplets. The tarnished film was mainly composed of oxides, sulfides, and chlorides of silver, copper and nickel. Even it was formed at moderate indoor conditions, experimental results showed that serious failure can occur in static contacts, sliding and fretting contacts as well.
  • Keywords
    contact resistance; corrosion testing; electrical contacts; environmental degradation; environmental testing; failure analysis; metallic thin films; reliability; silver; surface contamination; wear; 1500 A; 18 month; Ag; Ag contact surfaces; Ag plated surface; Ag-Ni; circular ring stain pattern; contact resistance; contaminated films; electric contact behavior; electric contact failure; fretting contacts; indoor air exposure; micro-cracks; natural air exposure; polarity effect; sliding contact behavior; static contacts; tarnished film; water droplets; Connectors; Contact resistance; Copper; Lubricants; Nickel; Silver; Surface contamination; Surface morphology; Surface resistance; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Contacts, 1996. Proceedings of the Forty-Second IEEE Holm Conference on ??. Joint with the 18th International Conference on Electrical Contacts
  • Conference_Location
    Chicago, IL, USA
  • Print_ISBN
    0-7803-3578-3
  • Type

    conf

  • DOI
    10.1109/HOLM.1996.557223
  • Filename
    557223