DocumentCode
2080831
Title
Cage-rotor induction machine axial leakage flux detection by parametric oscillation transducer
Author
Ejiogu, Emenike C. ; Kawabata, T. ; Tanno, T.
Author_Institution
Dept. of Electr. Eng., Ritsumeikan Univ., Kyoto, Japan
Volume
1
fYear
1996
fDate
1996
Firstpage
603
Abstract
When a reactance parameter of a resonance circuit is varied periodically, under appropriate conditions, an oscillation will occur. Then, by having a measured variable change, the value of the erstwhile constant reactance parameter, the oscillation voltage is modulated. Subsequent demodulation gives a signal proportional to the measured variable. In this paper we shall explain the basic principles of parametric oscillation in RLC and the application in realizing a transducer suitable for the sensing of the axial leakage flux of the induction motor
Keywords
demodulation; electric sensing devices; ferroresonant circuits; inductance; induction motors; machine testing; magnetic leakage; magnetic sensors; parametric oscillators; rotors; axial leakage flux detection; cage-rotor induction machine; demodulation; modulated oscillation voltage; parallel RLC circuit; parametric oscillation transducer; reactance parameter; resonance circuit; time-varying inductance; varactor diode; Amplitude modulation; Capacitance; Differential equations; Inductance; Induction machines; Leak detection; Magnetic cores; RLC circuits; Transducers; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Instrumentation and Measurement Technology Conference, 1996. IMTC-96. Conference Proceedings. Quality Measurements: The Indispensable Bridge between Theory and Reality., IEEE
Conference_Location
Brussels
Print_ISBN
0-7803-3312-8
Type
conf
DOI
10.1109/IMTC.1996.507453
Filename
507453
Link To Document