Title :
Calculating an appropriate multiplier for ßλ when modeling common cause failure in triplex systems
Author :
Bukowski, Julia V. ; Chalupa, Rudolf
Author_Institution :
Dept. of Electr. & Comput. Eng., Villanova Univ., Villanova, PA, USA
Abstract :
The Beta Model for common cause failure (CCF) is well accepted and has proven appropriate for dual architecture Safety Instrumented Systems (SIS). However, it is not directly applicable to a triplex architecture SIS. It has been suggested that CCF for a triplex architecture is appropriately modeled by αβλ. This paper derives α, the multiplier for βλ, required in the evaluation of CCF in triplex systems. It shows that the multiplier, α, varies between 1 and 1.5 as a function of the proportion of CCF which result in all three units of the triplex architecture failing. It further explains why, in the absence of reliable data on the proportion of CCF involving all three units, the most conservative safety evaluation requires setting the multiplier, α, to the value 1.5.
Keywords :
Markov processes; failure analysis; instrumentation; safety systems; appropriate multiplier calculation; beta model; common cause failure modeling; safety instrumented systems; triplex architecture; triplex systems; Instruments; Safety; Sampling methods; Stress; Virtual manufacturing; MESH model; PFDavg; beta model; common cause failures; safety instrumented systems; triplex architectures;
Conference_Titel :
Reliability and Maintainability Symposium (RAMS), 2010 Proceedings - Annual
Conference_Location :
San Jose, CA
Print_ISBN :
978-1-4244-5102-9
Electronic_ISBN :
0149-144X
DOI :
10.1109/RAMS.2010.5447996