DocumentCode :
2084090
Title :
Stress related failures and testing of inverter driven motors
Author :
Anderson, Jeff ; Lebruska, Scott
Author_Institution :
Baker Instrum. Co., Fort Collins, CO, USA
fYear :
1997
fDate :
22-25 Sep 1997
Firstpage :
151
Lastpage :
154
Abstract :
When first introduced, variable frequency drives (VFDs), also known as adjustable speed drives (ASDs) seemed to be an ideal tool for use in industrial production and process applications which used induction motors as prime movers. However, several negative effects, the most drastic of which was increased motor failures, resulted. This paper discusses some of these negative effects, some possible solutions and a predictive test method designed to avert such failures of induction motor insulation
Keywords :
DC-AC power convertors; electric breakdown; induction motor drives; insulation testing; invertors; machine insulation; machine testing; variable speed drives; adjustable speed drives; induction motor insulation failures; industrial production processes; insulation breakdown testing; motor failures; predictive test method; prime movers; variable frequency drives;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation Conference, 1997, and Electrical Manufacturing & Coil Winding Conference. Proceedings
Conference_Location :
Rosemont, IL
ISSN :
0362-2479
Print_ISBN :
0-7803-3959-2
Type :
conf
DOI :
10.1109/EEIC.1997.651023
Filename :
651023
Link To Document :
بازگشت