• DocumentCode
    2084335
  • Title

    Activation analysis for the LIBRA light ion beam fusion conceptual design

  • Author

    Sawan, Mohamed E.

  • Author_Institution
    Fusion Technol. Inst., Wisconsin Univ., Madison, WI, USA
  • fYear
    1989
  • fDate
    2-6 Oct 1989
  • Firstpage
    1393
  • Abstract
    Activation calculations have been performed for the LIBRA reactor. Replacing HT-9 with low-activation modified HT-9 increases the activity by a factor of 2.5 at shutdown while the long-term activity drops by a factor of 25. The reflector is classified as Class-C low-level waste when modified HT-9 is used. Using HT-9 will require deep geological burial for the LIBRA radiation waste. The activity produced in the Li 17Pb83 coolant has been determined. The major contributor to the coolant biological hazard potential (BHP) between a week and a year after shutdown is 210Po. During this period, the 210Po BHP values change from 7×105 to 1.2×105 km3 of air
  • Keywords
    fusion reactor materials; fusion reactor safety; radioactive waste; 210Po; Class-C low-level waste; LIBRA light ion beam fusion conceptual design; LIBRA reactor; Li17Pb83 coolant; coolant biological hazard potential; low-activation modified HT-9; Activation analysis; Concrete; Coolants; Fusion reactor design; Inductors; Ion beams; Iron alloys; Neutrons; Silicon carbide; Steel;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Fusion Engineering, 1989. Proceedings., IEEE Thirteenth Symposium on
  • Conference_Location
    Knoxville, TN
  • Type

    conf

  • DOI
    10.1109/FUSION.1989.102471
  • Filename
    102471