Design considerations for pressurized enclosures with containment systems according to the second edition of EN 50016
Author :
Osprey, J.S. ; Owler, A.M.
Author_Institution :
Servomex plc, UK
fYear :
1994
fDate :
19-21 Apr 1994
Firstpage :
136
Lastpage :
147
Abstract :
The second edition of EN 50016 introduces new concepts to cover the safety aspects associated with the explosion protection of electrical equipment which is intended to handle flammable substances in normal operation and which cannot be readily protected by other explosion protection. The definitions to clarify these concepts are briefly discussed. The authors deal with ignition capable apparatus, protected from an external flammable hazard, by being enclosed in a pressurized enclosure into which, for operational reasons, a flammable substance is introduced. The authors discuss the release conditions, the design requirements for the containment system, protective gas and pressurising technique, internal hot surfaces, enclosure testing, and the pressurisation test system
Keywords :
power apparatus; protection; safety; standards; EN 50016 second edition; containment systems; electrical equipment; enclosure testing; explosion protection; flammable substances handling; ignition capable apparatus; internal hot surfaces; pressurisation test system; pressurising technique; pressurized enclosures; protective gas; release conditions; safety;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Electrical Safety in Hazardous Environments, 1994., Fifth International Conference on
Conference_Location :
London
Print_ISBN :
0-85296-614-8
Type :
conf
DOI :
10.1049/cp:19940396
Filename :
324148
Link To Document :
بازگشت