• DocumentCode
    2085854
  • Title

    Experiments with nonintrusive diagnostic methods on a flameproof enclosure model

  • Author

    Beyer, M.

  • Author_Institution
    Physikalisch Tech. Bundesanstalt, Braunschweig, Germany
  • fYear
    1994
  • fDate
    19-21 Apr 1994
  • Firstpage
    40
  • Lastpage
    47
  • Abstract
    The transmission of an explosion through the gap of a flameproof enclosure is a complex combustion and flow process which is influenced by many different parameters. Investigations into this subject therefore require models of the enclosure and the gap, as well as nonintrusive measuring systems. In addition to the traditional schlieren method the use of laser diagnostic methods such as Rayleigh scattering and laser-induced fluorescence (LIF) are well suited to investigate fast combustion and flow processes. This paper describes the application of these methods on experiments outside the joint of a flameproof enclosure model
  • Keywords
    Rayleigh scattering; combustion; explosions; fluorescence; measurement by laser beam; schlieren systems; Rayleigh scattering; combustion; explosion transmission; flameproof enclosure model; flow process; laser diagnostic methods; laser-induced fluorescence; nonintrusive diagnostic methods; nonintrusive measuring systems; nozzles; schlieren method;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Electrical Safety in Hazardous Environments, 1994., Fifth International Conference on
  • Conference_Location
    London
  • Print_ISBN
    0-85296-614-8
  • Type

    conf

  • DOI
    10.1049/cp:19940382
  • Filename
    324162