DocumentCode :
2085854
Title :
Experiments with nonintrusive diagnostic methods on a flameproof enclosure model
Author :
Beyer, M.
Author_Institution :
Physikalisch Tech. Bundesanstalt, Braunschweig, Germany
fYear :
1994
fDate :
19-21 Apr 1994
Firstpage :
40
Lastpage :
47
Abstract :
The transmission of an explosion through the gap of a flameproof enclosure is a complex combustion and flow process which is influenced by many different parameters. Investigations into this subject therefore require models of the enclosure and the gap, as well as nonintrusive measuring systems. In addition to the traditional schlieren method the use of laser diagnostic methods such as Rayleigh scattering and laser-induced fluorescence (LIF) are well suited to investigate fast combustion and flow processes. This paper describes the application of these methods on experiments outside the joint of a flameproof enclosure model
Keywords :
Rayleigh scattering; combustion; explosions; fluorescence; measurement by laser beam; schlieren systems; Rayleigh scattering; combustion; explosion transmission; flameproof enclosure model; flow process; laser diagnostic methods; laser-induced fluorescence; nonintrusive diagnostic methods; nonintrusive measuring systems; nozzles; schlieren method;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Electrical Safety in Hazardous Environments, 1994., Fifth International Conference on
Conference_Location :
London
Print_ISBN :
0-85296-614-8
Type :
conf
DOI :
10.1049/cp:19940382
Filename :
324162
Link To Document :