DocumentCode
2086854
Title
Control parameter selection in auxiliary resonant commutated pole converters
Author
Teichmann, R.
Author_Institution
ABB Corporate Res., Ladenburg, Germany
Volume
2
fYear
2001
fDate
2001
Firstpage
862
Abstract
This paper addresses the optimum selection of the boost current and threshold current control parameters for the ARCP soft switching technique. The parameters are derived based on a minimization of the output voltage distortion induced by the ARCP operation. The impact of the proper selection of the resonant parameters on the system design is discussed
Keywords
commutation; electric current control; resonant power convertors; switching circuits; 100 kVA; 400 V; ARCP soft switching technique; auxiliary resonant commutated pole converters; auxiliary resonant commutated pole soft switching; boost current parameters; control parameter selection; equivalent circuit; output voltage distortion minimisation; threshold current control parameters; Capacitors; Resonance; Resonant inverters; Snubbers; Switches; Switching circuits; Threshold current; Voltage control; Zero current switching; Zero voltage switching;