  • Abstract
    This paper addresses the optimum selection of the boost current and threshold current control parameters for the ARCP soft switching technique. The parameters are derived based on a minimization of the output voltage distortion induced by the ARCP operation. The impact of the proper selection of the resonant parameters on the system design is discussed
  • Keywords
    commutation; electric current control; resonant power convertors; switching circuits; 100 kVA; 400 V; ARCP soft switching technique; auxiliary resonant commutated pole converters; auxiliary resonant commutated pole soft switching; boost current parameters; control parameter selection; equivalent circuit; output voltage distortion minimisation; threshold current control parameters; Capacitors; Resonance; Resonant inverters; Snubbers; Switches; Switching circuits; Threshold current; Voltage control; Zero current switching; Zero voltage switching;