DocumentCode
2087167
Title
TFTR neutral beam bellows redesign and calorimeter upgrade
Author
McDade, J. ; Dudek, L. ; Kaminsky, E. ; Lontai, L. ; Williams, M.
Author_Institution
Plasma Phys. Lab., Princeton Univ., NJ, USA
fYear
1989
fDate
2-6 Oct 1989
Firstpage
1459
Abstract
The TFTR (Tokamak Fusion Test Reactor) has experienced calorimeter bellows failures at lower duty cycles than anticipated. The history of the problems, and the analysis and testing that went into the solution of the problems within present design constraints are described. Guidelines for future bellows designs of this type and application (long stroke and vertical operation) are presented. Improvements incorporated in the other components associated with the calorimeter assembly are also described
Keywords
calorimeters; fusion reactor ignition; fusion reactor theory and design; TFTR neutral beam bellows redesign; Tokamak Fusion Test Reactor; calorimeter bellows failures; calorimeter upgrade; design constraints; long stroke; vertical operation; Bellows; Convolution; Fatigue; Image analysis; Laboratories; Physics; Plasmas; Stress; Testing; Welding;