• DocumentCode
    2087498
  • Title

    A 3D assessment tool for accurate volume measurement for monitoring the evolution of cutaneous Leishmaniasis wounds

  • Author

    Zvietcovich, F. ; Castaneda, B. ; Valencia, B. ; Llanos-Cuentas, Alejandro

  • Author_Institution
    Lab. of Med. Image Res., Pontificia Univ. Catolica del Peru, Lima, Peru
  • fYear
    2012
  • fDate
    Aug. 28 2012-Sept. 1 2012
  • Firstpage
    2025
  • Lastpage
    2028
  • Abstract
    Clinical assessment and outcome metrics are serious weaknesses identified on the systematic reviews of cutaneous Leishmaniasis wounds. Methods with high accuracy and low-variability are required to standarize study outcomes in clinical trials. This work presents a precise, complete and noncontact 3D assessment tool for monitoring the evolution of cutaneous Leishmaniasis (CL) wounds based on a 3D laser scanner and computer vision algorithms. A 3D mesh of the wound is obtained by a commercial 3D laser scanner. Then, a semi-automatic segmentation using active contours is performed to separate the ulcer from the healthy skin. Finally, metrics of volume, area, perimeter and depth are obtained from the mesh. Traditional manual 3D and 3D measurements are obtained as a gold standard. Experiments applied to phantoms and real CL wounds suggest that the proposed 3D assessment tool provides higher accuracy (error <;2%) and precision rates (error <;4%) than conventional manual methods (precision error <; 35%). This 3D assessment tool provides high accuracy metrics which deserve more formal prospective study.
  • Keywords
    area measurement; biomedical optical imaging; computer vision; image segmentation; laser applications in medicine; medical image processing; phantoms; skin; volume measurement; wounds; active contours; area metrics; clinical assessment; commercial 3D laser scanner; computer vision algorithms; conventional manual methods; cutaneous Leishmaniasis wound evolution monitoring; depth metrics; gold standard; healthy skin; noncontact 3D assessment tool; perimeter metrics; phantoms; precision rates; real CL wounds; semiautomatic segmentation; ulcer; volume measurement; wound 3D mesh; Accuracy; Manuals; Phantoms; Skin; Volume measurement; Wounds; Algorithms; Dermoscopy; Humans; Image Interpretation, Computer-Assisted; Imaging, Three-Dimensional; Leishmaniasis, Cutaneous; Pattern Recognition, Automated; Reproducibility of Results; Sensitivity and Specificity; Subtraction Technique;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-4119-8
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/EMBC.2012.6346355
  • Filename
    6346355