DocumentCode :
2090082
Title :
How long does a clock error remain inside two threshold barriers? An evaluation by means of stochastic processes
Author :
Panfilo, G. ; Tavella, P. ; Zucca, C.
fYear :
2004
fDate :
5-7 April 2004
Firstpage :
110
Lastpage :
115
Abstract :
In this paper we study the atomic clock error by using the stochastic differential equations. In particular, we focus on the evaluation of the "survival probability", that is the probability that clock error exceeds the limit of permissible error at a certain time after synchronization. The results are applied to experimental cases where the typical noise parameters of atomic clocks are considered. We also determine the optimal calibration intervals of measuring instruments as GNSS clock making use of the discussed results.
Keywords :
atomic clocks; calibration; differential equations; measurement errors; satellite navigation; stochastic processes; synchronisation; GNSS clock; atomic clock error; measuring instruments; optimal calibration interval; stochastic differential equation; stochastic process; survival probability; threshold barriers; PDE; SDE; clock error; synchronization;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Frequency and Time Forum, 2004. EFTF 2004. 18th European
Conference_Location :
Guildford
ISSN :
0537-9989
Print_ISBN :
0-86341-384-6
Type :
conf
Filename :
5074919