• DocumentCode
    2092043
  • Title

    A wearable vital signs monitor at the ear for continuous heart rate and Pulse Transit Time measurements

  • Author

    Winokur, Eric S. ; He, David Da ; Sodini, Charlie G.

  • Author_Institution
    Massachusetts Inst. of Technol., Cambridge, MA, USA
  • fYear
    2012
  • fDate
    Aug. 28 2012-Sept. 1 2012
  • Firstpage
    2724
  • Lastpage
    2727
  • Abstract
    A continuous, wearable and wireless vital signs monitor at the ear is demonstrated. The device has the form factor of a hearing aid and is wirelessly connected to a PC for data recording and analysis. The device monitors the electrocardiogram (ECG) in a single lead configuration, the ballistocardiogram (BCG) with a MEMS triaxial accelerometer, and the photoplethysmograms (PPG) with 660nm and 940nm LED sources and a static photocurrent subtraction analog front end. Clinical tests are conducted, including Valsalva and head-up tilt maneuvers. Peak timing intervals between the ECG, BCG and PPG are extracted and are shown to relate to pre-ejection period and mean arterial blood pressure (MAP). Pulse Transit Time (PTT) extracted from cross-correlation between the PPG and BCG shows improved results compared to the pulse arrival time (PAT) method for tracking changes in MAP.
  • Keywords
    accelerometers; bioMEMS; biomedical equipment; blood pressure measurement; data analysis; data recording; electrocardiography; light emitting diodes; medical signal processing; patient monitoring; photoconductivity; photoplethysmography; time measurement; BCG; ECG; LED sources; MAP; MEMS triaxial accelerometer; PC; PPG; PTT; ballistocardiogram; clinical tests; continuous heart rate measurements; data analysis; data recording; ear; electrocardiogram; head-up tilt maneuvers; hearing aid; mean arterial blood pressure; peak timing intervals; photoplethysmograms; preejection period; pulse transit time extraction; pulse transit time measurements; single lead configuration; static photocurrent subtraction analog front end; wavelength 660 nm; wavelength 940 nm; wearable vital sign monitor; wireless vital sign monitor; Biomedical monitoring; Ear; Electrocardiography; Heart; Light emitting diodes; Monitoring; Photoconductivity; Algorithms; Ballistocardiography; Blood Pressure; Ear; Electrocardiography; Heart Rate; Humans; Monitoring, Physiologic; Photoplethysmography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-4119-8
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/EMBC.2012.6346527
  • Filename
    6346527