DocumentCode
2092603
Title
CHIC: Cylindrical Helix Imaging Coordinate Registration Fiducial for MRI-guided interventions
Author
Yunzhao Ma ; Dobrev, I. ; Weijian Shang ; Hao Su ; Janga, S.R. ; Fischer, Gregory S.
Author_Institution
Dept. of Mech. Eng., Worcester Polytech. Inst., Worcester, MA, USA
fYear
2012
fDate
Aug. 28 2012-Sept. 1 2012
Firstpage
2808
Lastpage
2812
Abstract
Accurate placement of tubular shaped surgical tools is necessary for a large variety of image-guided medical interventions. In this process, localization of the instrument, or a robotic assistant manipulating the instrument, is crucial for successful registration of physical space to medical image space. Various fiducial frames and registration methods have been proposed and discussed in literature. However, these frames are typically bulky in size or otherwise not appropriate for use with MR imaging. In particular, it is impossible or awkward to integrate them with the surgical tools. This paper presents the design a compact Cylindrical Helix Imaging Coordinate Registration Fiducial (CHIC) and algorithm to precisely and robustly localize the frame in 6 degree of freedom (DOF). The mathematical model of the frame is developed and evaluated with simulation. This cylindrical shaped frame is particularly suitable for mounting to the distal end of tubular shape surgical tools, which provides a direct imaging visualization of frame, tool and possibly the surgical sites. The paper uses MRI-guided surgical procedure as a focusing application, although the broader aim is development of a versatile registration frame that is usable for a variety of image-guided procedures ranging from ultrasound to fluoroscopy and computerized tomography (CT). Accuracy and performance were evaluated in three cases: simulated images with artificial noise, arbitrarily re-sliced 3D MRI volume, and real 3T MRI images.
Keywords
biomedical MRI; image denoising; image registration; manipulators; medical image processing; medical robotics; surgery; MRI-guided medical interventions; arbitrarily resliced 3D MRI volume; artificial noise; computerized tomography; cylindrical helix imaging coordinate registration fiducial; cylindrical shaped frame; degree-of-freedom; direct imaging visualization; fluoroscopy; magnetic flux density 3 T; mathematical model; medical image space registration; physical space registration; robotic assistant manipulation; tubular shape surgical tools; ultrasound; versatile registration frame; Accuracy; Electron tubes; Magnetic resonance imaging; Mathematical model; Robot kinematics; Algorithms; Humans; Imaging, Three-Dimensional; Magnetic Resonance Imaging; Tomography, X-Ray Computed;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE
Conference_Location
San Diego, CA
ISSN
1557-170X
Print_ISBN
978-1-4244-4119-8
Electronic_ISBN
1557-170X
Type
conf
DOI
10.1109/EMBC.2012.6346548
Filename
6346548
Link To Document