DocumentCode
2093045
Title
A modified phase center and pattern matching method to reduce the geometry dependence of bilog calibration in standard site method
Author
Chen, Hsing-Feng ; Lin, Ken-Huang ; Chen, Cheng-Chang ; Tang, Yung-Chi
Author_Institution
Dept. of Electr. Eng., Nat. Sun Yat-Sen Univ., Kaohsiung
Volume
1
fYear
2005
fDate
12-12 Aug. 2005
Firstpage
90
Lastpage
92
Abstract
This study proposed a modified phase center and pattern matching (PCPM) method to reduce antenna factor (AF) variations of Bilog between different geometries of standard site method (SSM). For frequencies below 300 MHz, mutual coupling may have an effect on the results of original PCPM, thereby enlarging AF variations of Bilog. Therefore, a modified PCPM was applied with the results showing that AF variations of a Bilog can be reduced by 1.8 dB after modification
Keywords
antennas; calibration; pattern matching; Bilog calibration; antenna factor variations reduction; modified phase center; mutual coupling; pattern matching method; standard site method; Antenna measurements; Broadband antennas; Calibration; Dipole antennas; Frequency; Geometry; Log periodic antennas; Open area test sites; Pattern matching; Receiving antennas;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility, 2005. EMC 2005. 2005 International Symposium on
Conference_Location
Chicago, IL
Print_ISBN
0-7803-9380-5
Type
conf
DOI
10.1109/ISEMC.2005.1513479
Filename
1513479
Link To Document