Abstract
The limit values of the conductive noises on AC-mains are specified in normal operations of EUT by the regulation such as CISPR. Meanwhile, it has been said that the conductive noises generated on AC mains when AC power of EUT is turned on/off are larger than them in normal operations. In this paper, at first, it is shown that the conductive noises generated on AC-mains when AC power is turned on/off are lager than them in normal operations for commercially available equipments. Next, it is shown by using the proposed model circuit of EUT that one of the dominant factors for the conductive noises generated on AC-mains when AC power is turned on/off is the power factor of EUT.
Keywords
electronic equipment testing; interference suppression; noise; power factor; power supply quality; test equipment; AC power; AC-mains; CISPR; EUT; conductive noise; power factor; power on/off; AC generators; Circuit noise; Conductivity measurement; Electromagnetic interference; Electronic equipment; Noise generators; Noise measurement; Power generation; Power measurement; Reactive power;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility, 2005. EMC 2005. 2005 International Symposium on
Print_ISBN
0-7803-9380-5
Type
conf
DOI
10.1109/ISEMC.2005.1513486
Filename
1513486
Link To Document