DocumentCode :
2095957
Title :
Creep evaluation of (orthotic) cast materials during simulated clubfoot correction
Author :
Cohen, T.L. ; Altiok, H. ; Tarima, S. ; Smith, P.A. ; Harris, Gerald F.
Author_Institution :
Orthopaedic Rehabilitation & Eng. Res. Center (OREC), Marquette Univ., Milwaukee, WI, USA
fYear :
2012
fDate :
Aug. 28 2012-Sept. 1 2012
Firstpage :
3352
Lastpage :
3355
Abstract :
The Ponseti method is a widely accepted and highly successful conservative treatment of pediatric clubfoot that relies on weekly manipulations and cast applications. However, the material behavior of the cast in the Ponseti technique has not been investigated. The current study sought to characterize the ability of two standard casting materials to maintain the Ponseti corrected foot position by evaluating creep response. A dynamic cast testing device (DCTD) was built to simulate a typical pediatric clubfoot. Semi-rigid fiberglass and rigid fiberglass casting materials were applied to the device, and the rotational creep was measured at various constant torques. The movement was measured using a 3D motion capture system. A 2-way ANOVA was performed on the creep displacement data at a significance level of 0.05. Among cast materials, the rotational creep displacement was found to be significantly different (p-values ≪ 0.001). The most creep displacement occurs in the semi-rigid fiberglass (approximately 1.0 degrees), then the rigid fiberglass (approximately 0.4 degrees). There was no effect of torque magnitude on the creep displacement. All materials maintained the corrected position with minimal change in position over time.
Keywords :
biomechanics; biomedical equipment; biomedical materials; creep; glass fibres; medical disorders; orthotics; paediatrics; patient treatment; statistical analysis; torque; 2-way ANOVA; 3D motion capture system; Ponseti technique; SiO2; creep displacement data; dynamic cast testing device; highly successful conservative treatment; orthotic cast materials; rigid fiberglass casting materials; rotational creep displacement; semirigid fiberglass casting materials; simulated clubfoot correction; torque magnitude; typical pediatric clubfoot; Casting; Creep; Foot; Joints; Radio frequency; Torque; Analysis of Variance; Casts, Surgical; Child; Clubfoot; Humans; Materials Testing; Orthotic Devices;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE
Conference_Location :
San Diego, CA
ISSN :
1557-170X
Print_ISBN :
978-1-4244-4119-8
Electronic_ISBN :
1557-170X
Type :
conf
DOI :
10.1109/EMBC.2012.6346683