Title :
Over-load capacity of tubular permanent magnet linear motors
Author :
Benarous, Maamar ; Eastham, Fred
Author_Institution :
Goodrich Actuation Syst. Ltd., Wolverhampton
Abstract :
The magnetic limit on the force produced by a tubular permanent linear motor can be taken to be reached when the armature mmf is sufficient to reduce the magnet flux to zero in one area of the magnet. It is shown that this limit is greater when the construction uses embedded magnets than when surface magnets are used. In both cases the limit may be extended by the use of quadrature-axis flux barriers. These reduce the armature flux and therefore the demagnetizing effect whilst leaving the permanent magnet field largely unaffected.
Keywords :
demagnetisation; linear motors; magnetic flux; permanent magnet motors; armature mmf; demagnetizing effect; embedded magnets; magnet flux; over-load capacity; quadrature-axis flux barriers; surface magnets; tubular permanent magnet linear motors; Armature; Demagnetization; Finite element methods; Magnetic flux; Magnetic materials; Permanent magnet machines; Permanent magnet motors; Permanent magnets; Saturation magnetization; Temperature;
Conference_Titel :
Electric Machines and Drives Conference, 2009. IEMDC '09. IEEE International
Conference_Location :
Miami, FL
Print_ISBN :
978-1-4244-4251-5
Electronic_ISBN :
978-1-4244-4252-2
DOI :
10.1109/IEMDC.2009.5075268