DocumentCode
2097097
Title
Safety evaluation of walk-through metal detectors
Author
Wu, Dagang ; Qiang, Rui ; Chen, Ji ; Kainz, Wolfgang ; Seidman, Seth
Author_Institution
Dept. of Electr. & Comptuer Eng., Houston Univ., TX, USA
Volume
3
fYear
2005
fDate
8-12 Aug. 2005
Firstpage
796
Abstract
In this paper, we describe a procedure to evaluate the electrical current, induced by walk-through metal detectors electromagnetic emission, inside a human model for safety assessment. This procedure consists of the measurement of the magnetic field, the derivation of equivalent current source, and the calculation of induced current using the impedance method. This procedure is applied to determine for a commercial walk-through metal detector the induced currents within an anatomical human model.
Keywords
biological effects of fields; electromagnetic induction; safety; security; anatomical human model; electrical current; equivalent current source; impedance method; magnetic field measurement; safety assessment; safety evaluation; walk-through metal detectors; walk-through metal detectors electromagnetic emission; Current measurement; Detectors; Electromagnetic measurements; Electromagnetic radiation; Humans; Impedance measurement; Magnetic field measurement; Object detection; Probes; Safety;