DocumentCode :
2097973
Title :
Fabrication of high frequency (25-75 MHz) single element ultrasonic transducers
Author :
Cannata, J.M. ; Zhao, J.-Z. ; Ayyappan, S. ; Ritter, T.A. ; Chen, W. ; Shung, K. Kirk
Author_Institution :
NIH Resource Center for Med. Ultrasonic Transducer Eng., Pennsylvania State Univ., University Park, PA, USA
Volume :
2
fYear :
1999
fDate :
1999
Firstpage :
1099
Abstract :
The design and fabrication of high frequency single element ultrasonic transducers present a multitude of challenges for the transducer engineer, from size constraints to electrical impedance matching. This paper discusses the trade-offs involved in procedures used to fabricate lithium niobate (LiNbO3) and lead titanate (PbTiO3) transducers in the 25 MHz to 75 MHz range. Transducers of varying dimensions were built according to an f-number range of 2-3.5. Desired focal depths were achieved with use of either an acoustic lens or a spherically focused piezoceramic. Silver epoxy backing with an acoustic impedance of approximately 5.9 MRayls was used in all designs. All transducers were designed around a 50Ω send and receive circuit. Electrical tuning of the transducer to the receive circuitry was achieved by using an RF transformer and/or a length of coaxial cable. All transducers were tested in a pulse-echo arrangement using a Panametrics 5900PR pulser, a Wavetek function generator and a LeCroy digital oscilloscope. The bandwidth, insertion loss, and depth of focus were measured. Numerous transducers were fabricated with -6 dB bandwidths ranging from 40% to 74%, and two-way insertion loss values ranging from -14 dB to -28 dB
Keywords :
echo; impedance matching; lead compounds; lithium compounds; piezoelectric transducers; ultrasonic dispersion; ultrasonic focusing; ultrasonic transducers; -14 to -28 dB; 25 to 75 MHz; 50 ohm; Ag; LiNbO3; PbTiO3; RF transformer; acoustic lens; bandwidth; coaxial cable; depth of focus; design; electrical impedance matching; electrical tuning; f-number range; fabrication; focal depths; high frequency single element ultrasonic transducers; insertion loss; lead titanate; lithium niobate; pulse-echo arrangement; receive circuitry; send and receive circuit; silver epoxy backing; size constraints; spherically focused piezoceramic; trade-offs; two-way insertion loss; Acoustic transducers; Bandwidth; Circuits; Design engineering; Fabrication; Frequency; Impedance matching; Insertion loss; Pulse transformers; Ultrasonic transducers;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium, 1999. Proceedings. 1999 IEEE
Conference_Location :
Caesars Tahoe, NV
ISSN :
1051-0117
Print_ISBN :
0-7803-5722-1
Type :
conf
DOI :
10.1109/ULTSYM.1999.849191
Filename :
849191
Link To Document :