DocumentCode
2098101
Title
Calculation of radiated emission from the power line by 4-terminal pair network theory
Author
Shiozawa, Hirotaka ; Watanabe, Yousuke ; Tokuda, Masamitsu
Author_Institution
Res. Div. in Eng., Musashi Inst. of Technol., Tokyo, Japan
Volume
3
fYear
2005
fDate
8-12 Aug. 2005
Firstpage
996
Abstract
In order to obtain radiated emission characteristics from the power line, we measured the degree of unbalance to the earth and a leaked electric field from power line in high frequency band. The calculation model of power line is made by 4-terminal pair network theory, which has circuit constant as chain matrix of distributed constant on transmission line. The calculated value of TCTL (transverse conversion transmission loss) was mostly in agreement with measured value and then the validity of the calculation methods for TCTL was confirmed. The leaked electric field increases about 20 dB by grounding one of the pair line.
Keywords
carrier transmission on power lines; circuit theory; electric fields; losses; transmission line theory; 4-terminal pair network theory; chain matrix; circuit constant; distributed constant; leaked electric field; power line; radiated emission; transmission line; transverse conversion transmission loss; Distributed parameter circuits; Earth; Electric variables measurement; Frequency measurement; Power measurement; Power transmission lines; Propagation losses; Transmission line matrix methods; Transmission line measurements; Transmission line theory;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility, 2005. EMC 2005. 2005 International Symposium on
Print_ISBN
0-7803-9380-5
Type
conf
DOI
10.1109/ISEMC.2005.1513671
Filename
1513671