  • Abstract
    Noncathartic computed tomographic colonography (CTC) could significantly increase patient adherence to colorectal screening guidelines. However, radiologists find the interpretation of noncathartic CTC images challenging. We developed a fully automated computer-aided detection (CAD) scheme for assisting radiologists with noncathartic CTC. A volumetric method is used to detect lesions within a thick target region encompassing the colonic wall. Dual-energy CTC (DE-CTC) is used to provide more detailed information about the colon than what is possible with conventional CTC. False-positive detections are reduced by use of a random-forest classifier. The effect of the thickness of the target region on detection performance was assessed by use of 22 clinical noncathartic DE-CTC studies including 27 lesions ≥6 mm. The results indicate that the thickness parameter can have significant effect on detection accuracy. Leave-one-patient-out evaluation indicated that the proposed CAD scheme detects colorectal lesions at high accuracy in noncathartic CTC.
  • Keywords
    cancer; computerised tomography; decision trees; image classification; medical image processing; CAD scheme; automated computer-aided detection scheme; clinical noncathartic DE-CTC; colonic wall; colorectal lesions; colorectal screening guidelines; detection performance; dual-energy CTC; false-positive detections; leave-one-patient-out evaluation; noncathartic CTC image; noncathartic dual-energy computed tomographic colonography; patient adherence; radiologists; random-forest classifier; thickness parameter; volumetric detection; Colon; Colonography; Computed tomography; Design automation; Lesions; Materials; Sensitivity; Cathartics; Colon; Colonography, Computed Tomographic; Colorectal Neoplasms; Cone-Beam Computed Tomography; False Positive Reactions; Humans; Radiography, Abdominal;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-4119-8
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/EMBC.2012.6346780
  • Filename
    6346780