DocumentCode :
2099633
Title :
Vibration Failure Analysis during the Process of Exciter Transformation
Author :
Sun Tao ; Wang Xiaofang ; Wang Wei ; Yang Fengzhen
Author_Institution :
Sch. of Energy & Power Eng., Dalian Univ. of Technol., Dalian, China
fYear :
2010
fDate :
28-31 March 2010
Firstpage :
1
Lastpage :
4
Abstract :
In the exciter technical transformation process of a power plant, the vibration of turbo-generating unit exceeds the allowed region because the transformation plan is not proper and rigorous. Through the analysis and examination, it is found that great unbalance value of cantilever end of the shaft is the cause. The final solution plan is made according to the rules of the enterprise as well as the spot conditions.
Keywords :
cantilevers; exciters; failure analysis; turbogenerators; exciter transformation; power plant; turbogenerating unit; vibration failure analysis; Failure analysis; Frequency; Power engineering and energy; Power generation; Shafts; Spectrogram; Sun; System testing; Turbines; Vibrations;
fLanguage :
English