Abstract
In this paper, based on electrical machinery classical theory, the mathematical model of static steady operation for the huge hydro-generator is established, and the expressions of the static power characteristic and the static steady power limit are deduced. Reference on the design parameters of 1000 MW hydro-generator and 700 MW hydro-generator, the change laws of the static power characteristic and the power limit are obtained with simulation.
Keywords
hydroelectric generators; electrical machinery classical theory; huge hydrogenerator; power 1000 MW; power 700 MW; power limit; static power characteristic; static steady operation; Electronic mail; Equations; Hydroelectric power generation; Machinery; Mathematical model; Power system dynamics; Power system simulation; Power system stability; Reactive power; Voltage;