DocumentCode
2100847
Title
Pathological lesion detection in 3D dynamic PET images using asymmetry
Author
Chen, Zhe ; Feng, Dagan ; Cai, Weidong
Author_Institution
Sch. of Inf. technologies, Sydney Univ., NSW, Australia
fYear
2003
fDate
17-19 Sept. 2003
Firstpage
295
Lastpage
300
Abstract
This paper describes a segment-based asymmetry feature detection approach for three-dimensional positron emission tomography (PET) brain images to automatically extract pathological lesions. The method consists of three stages: preprocessing, segmentation, and asymmetry detection. The method was tested on simulation and clinical data sets and a per-pixel asymmetry feature detection is experimentally compared with our per-segment approach and the per-segment method is shown to produce fewer false positives and better demarcation in the PET data examples presented.
Keywords
brain; feature extraction; image segmentation; medical image processing; positron emission tomography; 3D dynamic PET images; asymmetry; automatic extraction; brain images; pathological lesion detection; per-segment method; preprocessing; segment-based feature detection; segmentation; three-dimensional positron emission tomography; Biomedical imaging; Computed tomography; Computer vision; Image segmentation; Lesions; Magnetic resonance imaging; Optical imaging; Pathology; Positron emission tomography; Ultrasonic imaging;
fLanguage
English
Publisher
ieee
Conference_Titel
Image Analysis and Processing, 2003.Proceedings. 12th International Conference on
Print_ISBN
0-7695-1948-2
Type
conf
DOI
10.1109/ICIAP.2003.1234066
Filename
1234066
Link To Document