DocumentCode :
2100871
Title :
Imaging the stiffness of the vitreous body with acoustic radiation force
Author :
Walker, William F. ; Negron, Laura A. ; Mondzelewski, Todd J. ; McAllister, M. Jason ; Fernandez, Francisco J. ; Toth, Cynthia A.
Author_Institution :
Dept. of Biomed. Eng., Virginia Univ., Charlottesville, VA, USA
Volume :
2
fYear :
1999
fDate :
1999
Firstpage :
1635
Abstract :
Tissue elasticity estimation is a major topic of ultrasound research. While most research focuses on cancer detection, the authors have concentrated on the detection of mechanical changes in the vitreous body of the eye. These changes are believed to contribute to retinal detachment. Thus, an accurate method of imaging vitreous mechanical properties might enable identification of patients at high risk before the presentation of symptoms. The authors are developing a new method of vitreous imaging which attempts to image tissue stiffness by applying acoustic radiation force. Force is applied at either a single location or along a line, with resultant target displacements estimated from returned echoes. This approach yields the dynamic response of targets to the applied forces. Images can be formed of the maximum induced displacement, or the relative elasticity and relative viscosity found by fitting experimental data to the Voigt model. The authors present B-Mode, maximum displacement, relative elasticity, and relative viscosity images of tissue mimicking phantoms and an enzymatically modified porcine eye. Images show the expected correlation between material stiffness and measured displacement. The potential of radiation force imaging was further explored by using a clinical ultrasound system to interrogate a phantom. At 84 mW/cm2 small displacements were visible in the B-Mode image, suggesting that measurable displacements may be generated at 50 mW/cm2, the historical FDA ophthalmic power limit
Keywords :
biomechanics; biomedical ultrasonics; elasticity; eye; B-Mode; Voigt model; acoustic radiation force; dynamic response; enzymatically modified porcine eye; material stiffness; maximum induced displacement; medical diagnostic imaging; medical ultrasound; ophthalmic power limit; patients identification; relative elasticity; relative viscosity images; retinal detachment; returned echoes; target displacements; tissue elasticity estimation; tissue mimicking phantoms; vitreous body stiffness imaging; Acoustic imaging; Acoustic signal detection; Cancer detection; Displacement measurement; Elasticity; Imaging phantoms; Retina; Ultrasonic imaging; Ultrasonic variables measurement; Viscosity;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium, 1999. Proceedings. 1999 IEEE
Conference_Location :
Caesars Tahoe, NV
ISSN :
1051-0117
Print_ISBN :
0-7803-5722-1
Type :
conf
DOI :
10.1109/ULTSYM.1999.849309
Filename :
849309
Link To Document :
بازگشت