Analysis of Magnetizing Surge in a No-Load Transformer during Blackstart
Author
Zhou Yunhai ; Wang Zhenggang ; Tanlicun ; Yin Wen
Author_Institution
Coll. of Electr. Eng. & Inf. Technol., China Three Gorges Univ., Yichang, China
fYear
2010
fDate
28-31 March 2010
Firstpage
1
Lastpage
4
Abstract
Notice of Retraction
After careful and considered review of the content of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE´s Publication Principles.
We hereby retract the content of this paper. Reasonable effort should be made to remove all past references to this paper.
The presenting author of this paper has the option to appeal this decision by contacting TPII@ieee.org.
It is analyzed the magnetizing surge which caused by a no-load transformer energization during black start which could make transformer differential protection and generator differential protection mal-operate. Taking a part of Hunan grids (230 kv transmission line from power plant in Zhexi to the transformer in Handing substation ) as an example, it is energized with two methods, which are energizing the transmission lines before energizing the no-load transformer and energizing the no-load transformer with transmission lines. Analyze the voltage, the current and the second harmonic of transformers and generator based on the simulation in the MATLAB of the two processes. It is concluded that those two methods don´t harm the power system, so energizing the transformer with transmission lines could be used during black start in this power system to reduce the steps and time of power restoration.
After careful and considered review of the content of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE´s Publication Principles.
We hereby retract the content of this paper. Reasonable effort should be made to remove all past references to this paper.
The presenting author of this paper has the option to appeal this decision by contacting TPII@ieee.org.
It is analyzed the magnetizing surge which caused by a no-load transformer energization during black start which could make transformer differential protection and generator differential protection mal-operate. Taking a part of Hunan grids (230 kv transmission line from power plant in Zhexi to the transformer in Handing substation ) as an example, it is energized with two methods, which are energizing the transmission lines before energizing the no-load transformer and energizing the no-load transformer with transmission lines. Analyze the voltage, the current and the second harmonic of transformers and generator based on the simulation in the MATLAB of the two processes. It is concluded that those two methods don´t harm the power system, so energizing the transformer with transmission lines could be used during black start in this power system to reduce the steps and time of power restoration.
Keywords
electric generators; power system restoration; power transformer protection; power transmission lines; surges; Hunan grids; MATLAB simulation; generator differential protection; magnetizing surge analysis; no-load transformer energization; power restoration; power system; transformer differential protection; transmission lines; Analytical models; Harmonic analysis; Magnetic analysis; Power generation; Power system harmonics; Power system restoration; Power system simulation; Power transmission lines; Substation protection; Surge protection;
fLanguage
English
Publisher
ieee
Conference_Titel
Power and Energy Engineering Conference (APPEEC), 2010 Asia-Pacific
Conference_Location
Chengdu
Print_ISBN
978-1-4244-4812-8
Type
conf
DOI
10.1109/APPEEC.2010.5448808
Filename
5448808
Link To Document