• DocumentCode
    2103263
  • Title

    Energy and energy width measurement in the FNAL antiproton accumulator

  • Author

    Church, M. ; Hsueh, S.Y. ; Rapidis, P.A. ; Werkema, S.

  • Author_Institution
    Fermi Nat. Accel. Lab., Batavia, IL, USA
  • fYear
    1991
  • fDate
    6-9 May 1991
  • Firstpage
    108
  • Abstract
    The Fermilab Antiproton Accumulator has been used to produce charmonium resonances (charm quark, anti-charm quark bound states) in proton-antiproton annihilations using an internal H/sub 2/ gas jet target. A measurement of the resonance mass and width may be obtained from a precise knowledge of the antiproton beam energy and energy spread. The beam energy is measured to an accuracy of one part in 10/sup 4/ in the range 6.3 GeV to 4.1 GeV by measuring the orbit length and resolution frequency of the beam. The beam momentum spread is measured to an accuracy of 10%. The two measurement techniques used are described.<>
  • Keywords
    particle beam diagnostics; proton accelerators; storage rings; 4.1 to 6.3 GeV; FNAL antiproton accumulator; Fermilab Antiproton Accumulator; antiproton; beam energy; beam momentum spread; energy width; orbit length; resolution frequency; Current measurement; Energy measurement; Extraterrestrial measurements; Frequency measurement; Length measurement; Magnetic field measurement; Proton accelerators; Resonance; Signal analysis; Uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
  • Conference_Location
    San Francisco, CA, USA
  • Print_ISBN
    0-7803-0135-8
  • Type

    conf

  • DOI
    10.1109/PAC.1991.164216
  • Filename
    164216