DocumentCode
2107365
Title
Insulation resistance measurements versus temperature made on aged stator bars and coils
Author
Zhu, H.
Author_Institution
Powertech Labs. Canada, Ontario, QC
fYear
2007
fDate
22-24 Oct. 2007
Firstpage
215
Lastpage
218
Abstract
The rule "insulation resistance halving for a 10 degC increase in temperature for rotating machine insulation" has been widely used in the industry. The rule was established based on testing of some insulation systems during the late 1950s. IEEE standard 43-2000 also provides a chart of the insulation resistance temperature coefficient versus temperature for correction of insulation resistance obtained at various temperatures based on this rule. However, it is unclear if this rule fits modern insulation systems. This paper presents laboratory tests on individual modern stator bars and coils to investigate insulation resistance versus temperature. The test results show that there is considerable discrepancy in the insulation resistance versus temperature characteristics between modern stator bars and old stator bars.
Keywords
ageing; electric machines; machine insulation; IEEE standard 43-2000; aged stator bars; coils; insulation resistance measurements; rotating machine insulation; temperature 10 degC; Aging; Coils; Electrical resistance measurement; Insulation testing; Laboratories; Modems; Rotating machines; Stator bars; System testing; Temperature measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation Conference and Electrical Manufacturing Expo, 2007
Conference_Location
Nashville, TN
Print_ISBN
978-1-4244-0446-9
Electronic_ISBN
978-1-4244-0447-6
Type
conf
DOI
10.1109/EEIC.2007.4562623